Skip to main content →
3S Genuine Consumables Desk • Pal Gaon, Jodhpur HQ

Genuine Compressor Fluids, Separators & CPCB4+ DG Oils

Counterfeit filters and automotive oils cost industrial plants ₹1.5L+ in prematurely glazed air-end rotors, separator fires, and plugged CPCB4+ DPF traps. Order verified part numbers directly with 100% GST tax invoices from M/s. Apex Engineering.

Atlas Copco genuine Roto Inject Fluid NDURANCE and Roto Xtend compressor oils
Genuine Atlas Copco preventive maintenance filter and separator service kit
Verified OEM Part Reference

Running Lubricants, Filters & Preventive Kit Schedule

Atlas Copco • Compressor LubricantPN 1630114600

Roto Inject Fluid NDURANCE (20L)

Formulation / Standard
Mineral + Anti-Oxidant Blend
Service Interval
4,000 hrs / 1 year

Fitment: GA / GA⁺ / G Series Fixed-Speed Oil-Injected Screw. Prevents high-ambient thermal breakdown and sludge formation in 45–50°C Basni/Jalore rooms.

GST Tax Invoice • Jodhpur HQ
Atlas Copco • Compressor LubricantPN 2901170000 / 2901170100

Roto Xtend Duty Fluid (5L / 20L PAO)

Formulation / Standard
Full Synthetic Polyalphaolefin
Service Interval
8,000 hrs / 2 years

Fitment: GA VSD⁺ / GA VSDˢ / High-Load Stationary Screw. Lower bearing friction and varnish immunity at varying VSD inverter RPMs.

GST Tax Invoice • Jodhpur HQ
Atlas Copco • Compressor LubricantPN 1630204105

Roto Synthetic Fluid ULTRA (20L)

Formulation / Standard
Heavy-Duty High-Temp Synthetic
Service Interval
4,000 hrs (Extreme Duty)

Fitment: X-Air⁺ & DrillAir High-Pressure Quarry Portables. Formulated specifically to protect 20–29.3 bar two-stage air-ends from varnish at quarry summer peaks.

GST Tax Invoice • Jodhpur HQ
Atlas Copco • Compressor LubricantPN 2908850101

Roto Z Fluid (20L)

Formulation / Standard
Oil-Free Element Gear & Timing Oil
Service Interval
Up to 16,000 hrs

Fitment: Z-Series Oil-Free Rotary Screw / Tooth / Blower. Protects precision timing gears and bearings inside Class-0 oil-free compressors.

GST Tax Invoice • Jodhpur HQ
Atlas Copco • ISO 8573-1 Line FilterDD⁺ / PD⁺ / UD⁺ / QD⁺

In-Line Coalescing & Carbon Filter Elements

Formulation / Standard
0.08 to 0.001 mg/m³ Oil Carryover
Service Interval
4,000 hrs or ΔP Indicator

Fitment: Laser Cutters, CNC Tooling, Pharma & Spray Lines. Glass-fiber pleated media keeps differential pressure low so your compressor never wastes extra kW.

GST Tax Invoice • Jodhpur HQ
Atlas Copco • Air-Oil Separator & PM Kit2901-XXXX-XX Series

Bundled 2,000 / 4,000 / 8,000-Hr Overhaul Kits

Formulation / Standard
Genuine Spin-On + Separator + MPV Seals
Service Interval
500 – 8,000 hrs Scheduled

Fitment: Matched by Machine Serial Number / Nameplate. Anti-static copper ground clip on separators eliminates dangerous static discharge inside pressure vessels.

GST Tax Invoice • Jodhpur HQ
Ashok Leyland • DG CPCB4+ LubricantGulf Leypower XLE 15W-40

Genuine Ashok Leyland Gulf Leypower XLE Oil

Formulation / Standard
Low-SAPS API CJ-4 / CK-4 Class
Service Interval
500 / 600 / 750 hrs (Model Specific)

Fitment: LP15–LP250 CPCB4+ CRDi + DOC/DPF/SCR Gensets. Mandatory ash-controlled oil chemistry — ordinary heavy oil plugs expensive CPCB4+ DPF/SCR traps.

GST Tax Invoice • Jodhpur HQ
Ashok Leyland • DG CPCB4+ LubricantAL-CPCB4-FILT-KIT

Dual-Stage Silica Air, Spin-On Lube & Fuel Strainer Kits

Formulation / Standard
Sub-Micron Common-Rail Tolerance
Service Interval
500 hrs / Desert Dust Pre-Check

Fitment: H2G4DM15 through A6G4DE250 & NEPTUNE Industrial. Protects high-pressure CRDi piezo injectors from Rajasthan quarry dust and high-sulfur fuel contamination.

GST Tax Invoice • Jodhpur HQ
Emergency Plant-Stoppage Desk • Priority Fault Triage

Compressor or DG Stopped? Run 60-Second Line Recovery Triage

When a factory air header drops or a crusher DG trips, every idle hour costs lakhs. Select your exact fault symptom and district to get immediate safe isolation checks plus a priority-routed dispatch message for Jodhpur HQ.

Direct Breakdown Hotline: +91 89684 34360
Do-Not-Restart Check • Protect Air-End / EngineJodhpur HQ Triage

High Discharge Temperature Protocol

  • 01.Do NOT keep resetting without inspection — overheating varnishes compressor rotors within minutes.
  • 02.Inspect oil cooler fins for quarry silica dust choke, check thermostatic bypass valve & verify Roto oil level.
  • 03.Snap a photo of the controller error screen + machine serial plate and tap Priority WhatsApp Triage below.
Direct Engineering Desk • Same-Day GST Quote

Request Sizing Check & Official Quotation

Share your site district, CFM/Bar air demand, kVA load, or part number. Receive direct engineering support and commercial pricing from Mr. Sumit Kumar at Jodhpur HQ.

Direct Phone Hotline+91 89684 34360
Call Desk →
Official RFQ Email[email protected]
Email RFQ →
Registered Commercial Identity
Plot No. 35, 36, Vaishali Shilpgram Pal Yojna, Pal Gaon, Jodhpur, Rajasthan - 342014
GSTIN: 08BIFPK1646G1ZCVendor KYC PDF →
Call HQWhatsAppRequest Quote